    Ražotājs: DIGITUS

    Digitus OnLine UPS system, 1500


    €450,74 ar pvn

    Artikuls: ST06385233
    Preces kods: DN-170094
    Ražotāja mājaslapa
    Garantija: 12 mēneši
    *
    Noliktava Piegāde Daudzums Cena
    PL
    PL
    LT
    LT
    LV

    Specifikācija
    Ligzda (RJ-45)
    Ligzda (IEC320)
    Ligzda (RS232)
    Ligzda (USB)
    Tips Online
    Tips Double Conversion Online
    Nominālais efekts (VA) 1500
    Akumulatori Akumulatori
    Apparent power1500 VA
    Active power1500 (Watt)
    UPS Architectureon-line double conversion
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    No. of batteries3
    Voltage12 (Volt)
    Battery capacity9 (Ah)
    Hold-up time (maks)0 (second)
    Charging time4 (Hour)
    Chassis typeRack
    Chassis typeTower
    Input power portsIEC-C14
    Output power ports8 x IEC-C13
    I/O connectors1 x USB (Type B)
    I/O connectors1 x RS-232 (COM)
    I/O connectors2 x RJ-45 LAN
    Environment requirements

    Wilgotność powietrza: 0-90% RH przy temp. od 0°C do +40 °C (bez skraplania)

    Accessories included
    • 1 x podręcznik użytkownika urządzenia
    • 1 x licencja z instrukcją instalacji oprogramowania
    • 1 x kabel przyłączeniowy USB, 1,2 m
    • 1 x przewód zasilający 1,8 m
    • 1 x kabel RS232
    ColorBlack
    Dimensions
    • (wys. x szer. x gł.): 86,5 (2U) x 440 x 460 mm
    • Rozstaw RACK (IEC 60297): 482.6 mm (19")
    Weight17.1 (kilogram)
    Other features
    • Wyższy współczynnik mocy wyjściowej przy 1,0 PF (współczynnik sprawności maks. 94,0%)
    • Wyłącznik EPO (awaryjne wyłączenie zasilania)
    • Napięcie wejściowe/wyjściowe: 200/208/220/230/240 VAC
    • Zakres napięcia: 110290 VAC 5%
    • Zakres częstotliwości: 45 Hz 70 Hz
    • Współczynnik mocy: 1,0 przy napięciu wyjściowym; 0,99 przy napięciu wejściowym
    • Regulacja napięcia: 1%
    • Zakres częstotliwości (zasięg zsynchronizowany): 50 Hz lub 60 Hz
    • Zakres częstotliwości (w trybie akumulatorowym): 50/60 Hz 0,1 Hz
    • Stosunek skokowych wzrostów poboru prądu: 3:1 (maks.)
    • Zniekształcenia harmoniczne (tryb sieciowy): 3% THD (ładunek liniowy); 6% THD (ładunek nieliniowy)
    • Czas przejścia (od trybu sieciowego do trybu akumulatorowego): zero
    • Czas przejścia (od falownika do bypassu): 4 ms (typowo)
    • Kształt fali (w trybie akumulatorowym): idealnie sinusoidalny
    • Wydajność: 90% (tryb prądu przemiennego); 85% (tryb akumulatorowy); 97% (tryb ECO)
    • Typowy czas ładowania: 4 godziny do przywrócenia 90% pojemności
    • Prąd ładowania: 2 A
    • Napięcie ładowania: 41,1 VDC 1%
    • Kompatybilność: Smart RS-232/USB obsługuje Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, FreeBSD oraz Mac
    • Przewód zasilający: 1,8 m, wtyczka ze stykiem ochronnym typu F (CEE 7/4) do gniazda żeńskiego z uziemieniem typu C14
    • Wyjścia: 8 x IEC C13, w tym 4 x programowalne
    • Kabel przyłączeniowy USB: USB A na USB B / 1,2 m
    • Plug: IEC 60320 C14 inlet
    • Power: 1500VA - 3000VA
    Width555
    Height595
    Depth202
    Weight16600
    Description

    Systemy UPS OnLine firmy DIGITUS to wyjątkowo niezawodne rozwiązania, które zostały opracowane z myślą o ochronie wrażliwych urządzeń przed przerwami w dopływie prądu. Są one wyposażone w mikroprocesory sterujące dla zagwarantowania najwyższej wydajności i bezpieczeństwa systemów firmowych i biurowych użytkownika, a także ochrony przed utratą danych i ewentualnymi szkodami. Dzięki wysokiemu współczynnikowi mocy, szerokiemu zakresowi napięcia oraz wydajnej ładowarce system nadaje się również do zastosowań o wysokich wymaganiach. Inteligentne tryby ładowania i sterowania prędkością obrotową wentylatorów wydłużają żywotność i zwiększają niezawodność UPS. Za pomocą wyświetlacza LCD można skonfigurować wszystkie ustawienia parametrów tego zasilacza awaryjnego dla zapewnienia nieprzerwanego zasilania elektrycznego. Adapter SNMP do zdalnego dostępu do systemu UPS jest dostępny opcjonalnie.

    • Podwójna konwersja online (sterowanie mikroprocesorem)
    • Możliwość przekształcenia w konstrukcję Rack/Tower
    • Inteligentny tryb ładowania
    • Obrotowy ekran LCD z wielofunkcyjną regulacją parametrów i schematem funkcji
    • Wyświetlacz LCD (status ładowania, status akumulatora, tryb prądu przemiennego, tryb akumulatorowy, tryb bypass, wskaźnik błędu)
    • Doskonała zdolność przeciążeniowa
    • Obsługiwany rozruch na zimno
    • Różnorodne wbudowane interfejsy do komunikacji (RS232/USB, złącze szeregowe, slot na karty SNMP)
    • Sterowanie za pomocą mikroprocesora optymalizuje niezawodność na wypadek przerwy w dostawie energii elektrycznej
    • Dostępna opcjonalnie karta SNMP umożliwia sterowanie zdalne za pośrednictwem sieci LAN
    Status14 dienas
    Description
    OnLine UPS Module, 1500VA/1500W

    The OnLine UPS is an ideal backup solution for your demanding power requirements and ensures fail-safe operation in a variety of industrial applications.

    High power factor (1.0), higher active power allows more connected loads, this saves space and reduces cost.
    High efficiency in online mode, higher efficiency means optimized power management and lower heat dissipation, resulting in energy savings and improved reliability.
    User-friendly LCD screen provides insight into UPS status for easy installation, configuration and operation.
    Compact rack/tower design optimizes rack space and allows for flexible installation.
    Minimized equipment downtime with hot-swappable, user-replaceable battery modules that can be replaced on the fly.
    External battery modules enable extended runtime.
    High number of outlets (8 x C13) for optimal power distribution to loads.
    Various communication interfaces (RS232/USB, parallel port, SNMP slot) allow remote monitoring of the system.
    Automatic battery self-test and fan speed control increase component life.
    Remote Emergency Power Off (REPO) function turns off the UPS during emergencies. When an emergency occurs, the REPO switch turns off the rectifier and inverter and immediately stops power to the load. The UPS stops charging and discharging the battery.

    The DIGITUS® OnLine UPS is a double-conversion UPS solution that provides best-in-class power failure protection and continuous power generation in a compact and flexible system. The single-phase UPS operates with high energy efficiency and is ideal for protecting critical infrastructure in both centralized and edge network applications. Scalable runtime options with matching external battery cabinets provide additional flexibility when extended uninterruptible power is required. The user-friendly LCD display and network management capability, including configuration, make this system easy to install and maintain. With market-leading efficiency and consistent power factor, the UPS meets your critical application needs.

    Installation: Desktop, Rack
    Plug: IEC 60320 C14 inlet
    Power: 1500VA – 3000VA
    Technology: Online double conversion
    Inch form factor (IEC 60297): 482.6 mm (19")
    Online double conversion system (VFI-SS-111)
    Input: socket IEC60320 C14, 208/220/230/240 Vac
    Output: 8 x IEC60320 C13, max. 10A per socket
    System power rating: 1500 VA / 1500 W, power factor 1.0
    AC-AC (online VFI) efficiency: 93 %, ECO mode efficiency: 98 %.
    Replaceable internal battery pack during operation.
    Battery: valve-regulated, non-spillable lead-acid battery.
    Battery capacity: 3 x 12V x 9.0 Ah
    Full load run time: 4 min; half load run time: 12 min
    Charge: 4 hours to 90% capacity after fully discharged
    Network connection: Optional SNMP/Webcard (part number DN-170100) allows remote monitoring of the UPS.
    Local communication ports: USB, RS-232 (serial), SNMP card (optional), relay card (optional)
    Emergency power-off (EPO) contact for UPS shutdown in case of emergency
    Maximum operating temperature: 0 - 40 °C
    Storage temperature: -25 - 55 °C
    Relative humidity: 20 - 90% non-condensing
    Operating altitude: < 1500 m
    Product dimensions WxDxH (mm): 440 (19") x 460 x 86.5 (2U)
    Product weight: 15,5 kg
    Shipping dimensions WxDxH (mm): 555 x 595 x 202
    Shipping weight: 20,2 kg
    Safety standards: IEC/EN62040-1,IEC/EN60950-1
    EMC standards: IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
    Approval: CE declaration
    Scope of delivery: UPS unit, feet for tower installation, UPS manual, UPS QSG, UPS software license, USB cable, mains cable (1.8m protective contact socket (type 7/4) to IEC60320 socket C14), IEC C13 connection cable, 19" installation brackets
    Optional available: 19" UPS mounting kit (profile rails), part number DN-170109

    Package content:
    1 x OnLine UPS system, 1500 VA / 1500 W
    1 x UPS user manual
    1 x USB connection cable 1.2 m
    1 x Mains cable 1.8 m
    1 x RS232 cable
    UPS software license
    19" installation brackets
    Feet for tower installation

    Platums(cm) 55.5
    Grums(cm) 59.5
    Augstums(cm) 20.2
    Svars(kg) 19.8
    Tilpums(cm3) 66705.5
    Izcelsmes valsts CN
    Gross depth (mm)565
    Gross height (mm)205
    Gross weight19.6
    Gross width (mm)595.00
    Net weight19.2
    Packing quantity1.00
    Paper/Pasteboard350.00
    Plastic (No PET)50.00
    Tare weight (kg)0.40
    TI weight (kg)19.00
    Volume (m3)0.068915875
    Classification of batteryCL126:NE:2016-12-09
    Composition of batteryCL127:KT:2016-12-09
    Type of batteryAccumulator
    Embeeded batteryYes
    WEEE taxYes
    WEE classificationCL109:6:2017-04-01
    Producer product nameOnLine UPS Modul, 1500VA/1500W
    UPS topologyOn line
    Capacity1500
    Capacity1500
    Other featuresEasy-to-use LCD screen provides insight into UPS status for easy installation, configuration and operation. Various communication interfaces (RS232/USB, parallel port, SNMP slot) enable remote monitoring of the system.
    Producer product familyOnLine UPS
    Palette Qty25
    ProducerDigitus
    Warranty24

    Specifikācija
    Ligzda (RJ-45)
    Ligzda (IEC320)
    Ligzda (RS232)
    Ligzda (USB)
    Tips Online
    Tips Double Conversion Online
    Nominālais efekts (VA) 1500
    Akumulatori Akumulatori
    Apparent power1500 VA
    Active power1500 (Watt)
    UPS Architectureon-line double conversion
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    No. of batteries3
    Voltage12 (Volt)
    Battery capacity9 (Ah)
    Hold-up time (maks)0 (second)
    Charging time4 (Hour)
    Chassis typeRack
    Chassis typeTower
    Input power portsIEC-C14
    Output power ports8 x IEC-C13
    I/O connectors1 x USB (Type B)
    I/O connectors1 x RS-232 (COM)
    I/O connectors2 x RJ-45 LAN
    Environment requirements

    Wilgotność powietrza: 0-90% RH przy temp. od 0°C do +40 °C (bez skraplania)

    Accessories included
    • 1 x podręcznik użytkownika urządzenia
    • 1 x licencja z instrukcją instalacji oprogramowania
    • 1 x kabel przyłączeniowy USB, 1,2 m
    • 1 x przewód zasilający 1,8 m
    • 1 x kabel RS232
    ColorBlack
    Dimensions
    • (wys. x szer. x gł.): 86,5 (2U) x 440 x 460 mm
    • Rozstaw RACK (IEC 60297): 482.6 mm (19")
    Weight17.1 (kilogram)
    Other features
    • Wyższy współczynnik mocy wyjściowej przy 1,0 PF (współczynnik sprawności maks. 94,0%)
    • Wyłącznik EPO (awaryjne wyłączenie zasilania)
    • Napięcie wejściowe/wyjściowe: 200/208/220/230/240 VAC
    • Zakres napięcia: 110290 VAC 5%
    • Zakres częstotliwości: 45 Hz 70 Hz
    • Współczynnik mocy: 1,0 przy napięciu wyjściowym; 0,99 przy napięciu wejściowym
    • Regulacja napięcia: 1%
    • Zakres częstotliwości (zasięg zsynchronizowany): 50 Hz lub 60 Hz
    • Zakres częstotliwości (w trybie akumulatorowym): 50/60 Hz 0,1 Hz
    • Stosunek skokowych wzrostów poboru prądu: 3:1 (maks.)
    • Zniekształcenia harmoniczne (tryb sieciowy): 3% THD (ładunek liniowy); 6% THD (ładunek nieliniowy)
    • Czas przejścia (od trybu sieciowego do trybu akumulatorowego): zero
    • Czas przejścia (od falownika do bypassu): 4 ms (typowo)
    • Kształt fali (w trybie akumulatorowym): idealnie sinusoidalny
    • Wydajność: 90% (tryb prądu przemiennego); 85% (tryb akumulatorowy); 97% (tryb ECO)
    • Typowy czas ładowania: 4 godziny do przywrócenia 90% pojemności
    • Prąd ładowania: 2 A
    • Napięcie ładowania: 41,1 VDC 1%
    • Kompatybilność: Smart RS-232/USB obsługuje Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, FreeBSD oraz Mac
    • Przewód zasilający: 1,8 m, wtyczka ze stykiem ochronnym typu F (CEE 7/4) do gniazda żeńskiego z uziemieniem typu C14
    • Wyjścia: 8 x IEC C13, w tym 4 x programowalne
    • Kabel przyłączeniowy USB: USB A na USB B / 1,2 m
    • Plug: IEC 60320 C14 inlet
    • Power: 1500VA - 3000VA
    Width555
    Height595
    Depth202
    Weight16600
    Description

    Systemy UPS OnLine firmy DIGITUS to wyjątkowo niezawodne rozwiązania, które zostały opracowane z myślą o ochronie wrażliwych urządzeń przed przerwami w dopływie prądu. Są one wyposażone w mikroprocesory sterujące dla zagwarantowania najwyższej wydajności i bezpieczeństwa systemów firmowych i biurowych użytkownika, a także ochrony przed utratą danych i ewentualnymi szkodami. Dzięki wysokiemu współczynnikowi mocy, szerokiemu zakresowi napięcia oraz wydajnej ładowarce system nadaje się również do zastosowań o wysokich wymaganiach. Inteligentne tryby ładowania i sterowania prędkością obrotową wentylatorów wydłużają żywotność i zwiększają niezawodność UPS. Za pomocą wyświetlacza LCD można skonfigurować wszystkie ustawienia parametrów tego zasilacza awaryjnego dla zapewnienia nieprzerwanego zasilania elektrycznego. Adapter SNMP do zdalnego dostępu do systemu UPS jest dostępny opcjonalnie.

    • Podwójna konwersja online (sterowanie mikroprocesorem)
    • Możliwość przekształcenia w konstrukcję Rack/Tower
    • Inteligentny tryb ładowania
    • Obrotowy ekran LCD z wielofunkcyjną regulacją parametrów i schematem funkcji
    • Wyświetlacz LCD (status ładowania, status akumulatora, tryb prądu przemiennego, tryb akumulatorowy, tryb bypass, wskaźnik błędu)
    • Doskonała zdolność przeciążeniowa
    • Obsługiwany rozruch na zimno
    • Różnorodne wbudowane interfejsy do komunikacji (RS232/USB, złącze szeregowe, slot na karty SNMP)
    • Sterowanie za pomocą mikroprocesora optymalizuje niezawodność na wypadek przerwy w dostawie energii elektrycznej
    • Dostępna opcjonalnie karta SNMP umożliwia sterowanie zdalne za pośrednictwem sieci LAN
    Status14 dienas
    Description
    OnLine UPS Module, 1500VA/1500W

    The OnLine UPS is an ideal backup solution for your demanding power requirements and ensures fail-safe operation in a variety of industrial applications.

    High power factor (1.0), higher active power allows more connected loads, this saves space and reduces cost.
    High efficiency in online mode, higher efficiency means optimized power management and lower heat dissipation, resulting in energy savings and improved reliability.
    User-friendly LCD screen provides insight into UPS status for easy installation, configuration and operation.
    Compact rack/tower design optimizes rack space and allows for flexible installation.
    Minimized equipment downtime with hot-swappable, user-replaceable battery modules that can be replaced on the fly.
    External battery modules enable extended runtime.
    High number of outlets (8 x C13) for optimal power distribution to loads.
    Various communication interfaces (RS232/USB, parallel port, SNMP slot) allow remote monitoring of the system.
    Automatic battery self-test and fan speed control increase component life.
    Remote Emergency Power Off (REPO) function turns off the UPS during emergencies. When an emergency occurs, the REPO switch turns off the rectifier and inverter and immediately stops power to the load. The UPS stops charging and discharging the battery.

    The DIGITUS® OnLine UPS is a double-conversion UPS solution that provides best-in-class power failure protection and continuous power generation in a compact and flexible system. The single-phase UPS operates with high energy efficiency and is ideal for protecting critical infrastructure in both centralized and edge network applications. Scalable runtime options with matching external battery cabinets provide additional flexibility when extended uninterruptible power is required. The user-friendly LCD display and network management capability, including configuration, make this system easy to install and maintain. With market-leading efficiency and consistent power factor, the UPS meets your critical application needs.

    Installation: Desktop, Rack
    Plug: IEC 60320 C14 inlet
    Power: 1500VA – 3000VA
    Technology: Online double conversion
    Inch form factor (IEC 60297): 482.6 mm (19")
    Online double conversion system (VFI-SS-111)
    Input: socket IEC60320 C14, 208/220/230/240 Vac
    Output: 8 x IEC60320 C13, max. 10A per socket
    System power rating: 1500 VA / 1500 W, power factor 1.0
    AC-AC (online VFI) efficiency: 93 %, ECO mode efficiency: 98 %.
    Replaceable internal battery pack during operation.
    Battery: valve-regulated, non-spillable lead-acid battery.
    Battery capacity: 3 x 12V x 9.0 Ah
    Full load run time: 4 min; half load run time: 12 min
    Charge: 4 hours to 90% capacity after fully discharged
    Network connection: Optional SNMP/Webcard (part number DN-170100) allows remote monitoring of the UPS.
    Local communication ports: USB, RS-232 (serial), SNMP card (optional), relay card (optional)
    Emergency power-off (EPO) contact for UPS shutdown in case of emergency
    Maximum operating temperature: 0 - 40 °C
    Storage temperature: -25 - 55 °C
    Relative humidity: 20 - 90% non-condensing
    Operating altitude: < 1500 m
    Product dimensions WxDxH (mm): 440 (19") x 460 x 86.5 (2U)
    Product weight: 15,5 kg
    Shipping dimensions WxDxH (mm): 555 x 595 x 202
    Shipping weight: 20,2 kg
    Safety standards: IEC/EN62040-1,IEC/EN60950-1
    EMC standards: IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
    Approval: CE declaration
    Scope of delivery: UPS unit, feet for tower installation, UPS manual, UPS QSG, UPS software license, USB cable, mains cable (1.8m protective contact socket (type 7/4) to IEC60320 socket C14), IEC C13 connection cable, 19" installation brackets
    Optional available: 19" UPS mounting kit (profile rails), part number DN-170109

    Package content:
    1 x OnLine UPS system, 1500 VA / 1500 W
    1 x UPS user manual
    1 x USB connection cable 1.2 m
    1 x Mains cable 1.8 m
    1 x RS232 cable
    UPS software license
    19" installation brackets
    Feet for tower installation

    Platums(cm) 55.5
    Grums(cm) 59.5
    Augstums(cm) 20.2
    Svars(kg) 19.8
    Tilpums(cm3) 66705.5
    Izcelsmes valsts CN
    Gross depth (mm)565
    Gross height (mm)205
    Gross weight19.6
    Gross width (mm)595.00
    Net weight19.2
    Packing quantity1.00
    Paper/Pasteboard350.00
    Plastic (No PET)50.00
    Tare weight (kg)0.40
    TI weight (kg)19.00
    Volume (m3)0.068915875
    Classification of batteryCL126:NE:2016-12-09
    Composition of batteryCL127:KT:2016-12-09
    Type of batteryAccumulator
    Embeeded batteryYes
    WEEE taxYes
    WEE classificationCL109:6:2017-04-01
    Producer product nameOnLine UPS Modul, 1500VA/1500W
    UPS topologyOn line
    Capacity1500
    Capacity1500
    Other featuresEasy-to-use LCD screen provides insight into UPS status for easy installation, configuration and operation. Various communication interfaces (RS232/USB, parallel port, SNMP slot) enable remote monitoring of the system.
    Producer product familyOnLine UPS
    Palette Qty25
    ProducerDigitus
    Warranty24
    Nesen skatītās preces