Close
(0) priekšmeti
You have no items in your shopping cart.
Visas kategorijas
    Filters
    Valoda
    Meklēt
    Ražotājs: LEGRAND

    Zasilacz awaryjny Keor SPE Rack 2U 3kVA


    €1400,27 ar pvn

    Artikuls: ST07702862
    Preces kods: 311072
    Ražotāja mājaslapa
    Garantija: 24 mēneši
    *
    Noliktava Piegāde Daudzums Cena
    PL

    Specifikācija
    Ligzda (IEC320)
    Nominālais efekts (VA) 3000
    Tips Line Interactive
    Ligzda (USB)
    Ligzda (RS232)
    Izejas jauda 2700
    Apparent power3000 VA
    Active power2700 (Watt)
    UPS Architectureline-interactive
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    No. of batteries6
    Voltage6 (Volt)
    Battery capacity9 (Ah)
    Charging time4 (Hour)
    Chassis typeRack
    Filters / protectionThermal
    Filters / protectionCircuit
    Filters / protectionAgainst reverse current
    Filters / protectionOverload
    Input power portsIEC-C20
    Output power ports8 x IEC-C13
    Output power ports1 x IEC-C19
    I/O connectors1 x RS-232 (COM)
    I/O connectors1 x USB (Type B)
    I/O connectors1 x EPO
    Environment requirements
    • Temperatura robocza (°C): 0 - 40
    • Wilgotność względna (%): 0-95 bez kondensacji
    • Poziom hałasu w odległości 1 m (dBA): poniżej 50
    • Szacunkowa zawartość materiałów pochodzących z gospodarki o obiegu zamkniętym: w przybliżeniu 41%
    • Wskaźnik przydatności do recyklingu obliczony przy użyciu metody opisanej w raporcie technicznym IEC/TR 62635: w przybliżeniu 78%
    ColorBlack
    Dimensions

    440 x 86,5 x 600 mm (2U)

    Weight29.3 (kilogram)
    DesignationCE+WEEE
    Width600
    Height200
    Depth800
    Weight20000
    Description

    Zasilacz awaryjny Keor SPE Rack 2U 3kVA

    Legrand KEOR SPE R/T 2200 to bezprzerwowy zasilacz UPS wykonany w technologii Line interactive o mocy znamionowej 3000VA - 2700W. Pracą urządzenia zarządza wysokiej jakości dedykowany mikroprocesor. Zasilacz posiada możliwość uruchomienia testów auto diagnostycznych oraz funkcję zimnego rozruchu. Zasilacz KEOR SPE RT może być używany zarówno w konfiguracjach typu tower, jak i rack.

    KEOR SPE R/T 3000 został wyposażony w hermetycznie zamknięte akumulatory ołowiowe z regulowanym zaworem, które gwarantują minimalny czas podtrzymania wynoszący 8 minut przy 80% obciążenia. Akumulatory można łatwo wymienić dzięki specjalnym pokrywom znajdującym się z przodu zasilacza UPS.

    Obecność elektronicznego stabilizatora napięcia (AVR) w zasilaczu zapewnia wysoką stabilność napięcia wyjściowego oraz skuteczną ochronę przed zakłóceniami w sieci elektrycznej.

    Zasilacz UPS posiada szereg gniazd wyjściowych 2 x (4 x IEC320-C13) + (1 x IEC 320-C19) przy czym jedna grupa gniazd może być programowalna. KEOR SPE R/T 3000 może być podłączony do komputera PC poprzez port SNMP, USB lub szeregowy RS232, co pozwala na wygodne monitorowanie jego pracy, za pomocą darmowego oprogramowania, a także na awaryjne wyłączenie systemów operacyjnych Windows oraz Linux.

    Zasilacz posiada 5-przyciskowy panel sterowania, ekran LCD oraz 3 diody LED stanu pracy zasilacza:

    • ZIELONA: Poprawna praca. Obciążenie jest zabezpieczone.
    • ŻÓŁTA: Obciążenie jest zasilane z baterii UPS, ale alarm jest aktywny, wymagana jest kontrola.
    • CZERWONA: obciążenie nie jest zasilane przez UPS. Występuje stan awaryjny.

    Wyświetlacz LCD pozwala odczytać:

    • Tryb pracy
    • Pomiary:

    a) Napięcie wejściowe oraz wyjściowe/częstotliwość
    b) Moc czynna i pozorna
    c) Procent obciążenia
    d) Napięcie akumulatora
    e) Procent naładowania akumulatora
    f) Czas podtrzymania
    g) Temperatura otoczenia

    • Alarmy i błędy

    Zasilacz KEOR SPE R/T 3000 posiada oznaczenie CE zgodnie z dyrektywami 2014/35 i 2014/30 oraz został zaprojektowany i zbudowany zgodnie z następującymi normami:

    • EN 62040-1 "Wymagania ogólne i bezpieczeństwa dotyczące zasilaczy UPS stosowanych w miejscach dostępnych dla operatora"
    • EN 62040-2 "Wymagania dotyczące kompatybilności elektromagnetycznej (EMC)"
    • EN 62040-3 "Wymagania dotyczące właściwości użytkowych i metod badań"

    Specifikācija
    Ligzda (IEC320)
    Nominālais efekts (VA) 3000
    Tips Line Interactive
    Ligzda (USB)
    Ligzda (RS232)
    Izejas jauda 2700
    Apparent power3000 VA
    Active power2700 (Watt)
    UPS Architectureline-interactive
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    No. of batteries6
    Voltage6 (Volt)
    Battery capacity9 (Ah)
    Charging time4 (Hour)
    Chassis typeRack
    Filters / protectionThermal
    Filters / protectionCircuit
    Filters / protectionAgainst reverse current
    Filters / protectionOverload
    Input power portsIEC-C20
    Output power ports8 x IEC-C13
    Output power ports1 x IEC-C19
    I/O connectors1 x RS-232 (COM)
    I/O connectors1 x USB (Type B)
    I/O connectors1 x EPO
    Environment requirements
    • Temperatura robocza (°C): 0 - 40
    • Wilgotność względna (%): 0-95 bez kondensacji
    • Poziom hałasu w odległości 1 m (dBA): poniżej 50
    • Szacunkowa zawartość materiałów pochodzących z gospodarki o obiegu zamkniętym: w przybliżeniu 41%
    • Wskaźnik przydatności do recyklingu obliczony przy użyciu metody opisanej w raporcie technicznym IEC/TR 62635: w przybliżeniu 78%
    ColorBlack
    Dimensions

    440 x 86,5 x 600 mm (2U)

    Weight29.3 (kilogram)
    DesignationCE+WEEE
    Width600
    Height200
    Depth800
    Weight20000
    Description

    Zasilacz awaryjny Keor SPE Rack 2U 3kVA

    Legrand KEOR SPE R/T 2200 to bezprzerwowy zasilacz UPS wykonany w technologii Line interactive o mocy znamionowej 3000VA - 2700W. Pracą urządzenia zarządza wysokiej jakości dedykowany mikroprocesor. Zasilacz posiada możliwość uruchomienia testów auto diagnostycznych oraz funkcję zimnego rozruchu. Zasilacz KEOR SPE RT może być używany zarówno w konfiguracjach typu tower, jak i rack.

    KEOR SPE R/T 3000 został wyposażony w hermetycznie zamknięte akumulatory ołowiowe z regulowanym zaworem, które gwarantują minimalny czas podtrzymania wynoszący 8 minut przy 80% obciążenia. Akumulatory można łatwo wymienić dzięki specjalnym pokrywom znajdującym się z przodu zasilacza UPS.

    Obecność elektronicznego stabilizatora napięcia (AVR) w zasilaczu zapewnia wysoką stabilność napięcia wyjściowego oraz skuteczną ochronę przed zakłóceniami w sieci elektrycznej.

    Zasilacz UPS posiada szereg gniazd wyjściowych 2 x (4 x IEC320-C13) + (1 x IEC 320-C19) przy czym jedna grupa gniazd może być programowalna. KEOR SPE R/T 3000 może być podłączony do komputera PC poprzez port SNMP, USB lub szeregowy RS232, co pozwala na wygodne monitorowanie jego pracy, za pomocą darmowego oprogramowania, a także na awaryjne wyłączenie systemów operacyjnych Windows oraz Linux.

    Zasilacz posiada 5-przyciskowy panel sterowania, ekran LCD oraz 3 diody LED stanu pracy zasilacza:

    • ZIELONA: Poprawna praca. Obciążenie jest zabezpieczone.
    • ŻÓŁTA: Obciążenie jest zasilane z baterii UPS, ale alarm jest aktywny, wymagana jest kontrola.
    • CZERWONA: obciążenie nie jest zasilane przez UPS. Występuje stan awaryjny.

    Wyświetlacz LCD pozwala odczytać:

    • Tryb pracy
    • Pomiary:

    a) Napięcie wejściowe oraz wyjściowe/częstotliwość
    b) Moc czynna i pozorna
    c) Procent obciążenia
    d) Napięcie akumulatora
    e) Procent naładowania akumulatora
    f) Czas podtrzymania
    g) Temperatura otoczenia

    • Alarmy i błędy

    Zasilacz KEOR SPE R/T 3000 posiada oznaczenie CE zgodnie z dyrektywami 2014/35 i 2014/30 oraz został zaprojektowany i zbudowany zgodnie z następującymi normami:

    • EN 62040-1 "Wymagania ogólne i bezpieczeństwa dotyczące zasilaczy UPS stosowanych w miejscach dostępnych dla operatora"
    • EN 62040-2 "Wymagania dotyczące kompatybilności elektromagnetycznej (EMC)"
    • EN 62040-3 "Wymagania dotyczące właściwości użytkowych i metod badań"