    Products specifications
    Socket (USB) yes
    Socket (IEC320) yes
    UPS voltage regulators 3000
    Socket (RJ-45) yes
    Tips Line Interactive
    Apparent power3000 VA
    Active power1950 (Watt)
    UPS Architectureline-interactive
    Number of phases input1 (230V)
    No. of batteries4
    Voltage230 (Volt)
    Battery capacity7 (Ah)
    Hold-up time (maks)3 (millisecond)
    Backup time (100% load)3 (Minute)
    Charging time7 (Hour)
    Chassis typeRack
    Filters / protectionOverload
    Filters / protectionSurge
    Filters / protectionCircuit
    Input power portsIEC-C20
    Output power ports6 x IEC-C13
    I/O connectors1 x USB (Type B)
    I/O connectors2 x RJ-45 LAN
    ColorBlack
    Dimensions
    • Wysokość: 132 (3U) mm
    • Szerokość: 483 (19) mm
    • Głębokość: 400 mm
    Weight31 (kilogram)
    Other features
    • Zastosowanie: Małe biuro i dom, Serwerownia
    • Temperatury pracy [°C]: 0 ÷ +40
    • Chłodzenie: Naturalne
    • Znamionowe napięcie wejściowe (wartość skuteczna) [V]:     ~ 230
    • Zakres napięcia wejściowego (wartości skuteczne) [V] i tolerancja [%]:     ~ 160 ÷ 264 (145 ÷ 280) 2
    • Częstotliwość znamionowa napięcia wejściowego [Hz]: 50
    • Zakres częstotliwości wejściowej [Hz] i tolerancja [Hz]: 45 ÷ 55 1
    • Progi przełączania: sieć UPS [V]: ~ 160 ÷ 264 (145 ÷ 280) 2 %
    • Znamionowe napięcie wyjściowe (wartość skuteczna) [V]:     ~ 230
    • Zakres napięcia wyjściowego (wartości skuteczne) [V] i tolerancja [%] - praca sieciowa : ~ 184 ÷ 264 (167 ÷ 280) 2
    • Zakres napięcia wyjściowego (wartości skuteczne) [V] i tolerancja [%] - praca rezerwowa : ~ 230 5
    • Kształt napięcia wyjściowego (przy pracy rezerwowej / sieciowej): Sinusoidalny / Tak jak na wejściu
    • Częstotliwość znamionowa napięcia wyjściowego [Hz]: 50
    • Zakres częstotliwości (tolerancja) - praca sieciowa [Hz]: Synchronicznie z siecią
    • Zakres częstotliwości (tolerancja) - praca rezerwowa [Hz]: 50 1
    • Filtracja napięcia wyjściowego : LC, filtr przeciwzakłóceniowy RFI/EMI, tłumik warystorowy
    • Progi przełączania: UPS sieć [V]: ~ 165 / 259 (150 / 275) 2 %
    • Czas przełączenia na pracę rezerwową [ms]: < 3
    • Czas powrotu na pracę sieciową [ms]: 0
    • Akumulatory wewnętrzne: 12 V / 7 Ah VRLA
    • Czas podtrzymania z baterii wewnętrznych (100 % / 80 % / 50 % Pmax) [min]: 3 / 4 / 8
    • Napięcie nominalne obwodu DC [V]: 48
    • Maksymalny czas ładowania baterii wewnętrznych UPS - po 80 % wyładowaniu baterii [h]: 7
    • Pozycja transportu: pozioma
    • Maksymalna długość przewodów wyjściowych [m]: < 10
    • Sygnalizacja: Akustyczno optyczna; diodowa
    • Filtr teleinformatyczny (linii danych) - RJ45: LAN 1 Gbit/s
    • Oprogramowanie monitorująco-zarządzające: PowerSoft Professional
    • Zimny start: tak
    Width500
    Height210
    Depth530
    Weight33000
    Description

    Generacja zasilaczy serii SINLINE USB HID umożliwia pełną ochronę zasilania zaawansowanych serwerów jedno i wieloprocesorowych, komputerów PC, terminali komputerowych oraz małych i średnich sieci.

    Cechy charakterystyczne:

    • Układ automatycznej regulacji napięcia sieciowego AVR (podwyższający) - umożliwia dostosowanie nieprawidłowego napięcia wejściowego do poziomu akceptowalnego przez odbiorniki bez użycia akumulatorów.
    • System Clear Digital Sinus (CDS) - umożliwia generację na wyjściu zasilacza UPS napięcia o czystym, sinusoidalnym kształcie przy pracy bateryjnej.
    • System Cool Battery Charging (CBC) - szybki i sprawny układ ładowania, który powoduje skrócenie czasu ładowania oraz wydłużenie okresu eksploatacji akumulatora zasilacza awaryjnego.
    • Zabezpieczenia przeciążeniowe, przeciwzwarciowe, przeciwprzepięciowe, przed nieprawidłowym podłączeniem.
    • Filtr sieci LAN (1 Gbit/s) umożliwia zabezpieczenie karty sieciowej przed skutkami oddziaływania przepięć.
    • Interfejs komunikacyjny USB HID zgodny z HID Power Devices możliwość współpracy UPS-a z innymi urządzeniami bez konieczności instalowania oprogramowania (zasilacz widoczny w systemie jako bateria).
    • Zimny start - możliwość uruchomienia urządzenia bez podłączenia do  sieci zasilającej
    • Sygnalizacja akustyczno-optyczna

    Rozszerzone progi przełączania (możliwe do ustawienia za pomocą oprogramowania PowerSoft) o następujących wartościach:

    • Sieć - ups: ~145V - ~280V +/- 2%
    • Ups - sieć: ~150V - ~275V +/- 2%
    • PowerSoft Professional bezpłatne oprogramowanie monitorująco - zarządzające pracą zasilaczy
    • Zaawansowana konfiguracja zdarzeń - możliwość tworzenia reguł uwarunkowanych od trybów pracy zasilacza, komunikatów oraz alarmów.
    • Opóźnienie przed ponownym załączeniem wyjścia zasilacza (wykorzystywane z opcją ponownego załączenia komputerów w systemach BIOS)

    Products specifications
    Socket (USB) yes
    Socket (IEC320) yes
    UPS voltage regulators 3000
    Socket (RJ-45) yes
    Tips Line Interactive
    Apparent power3000 VA
    Active power1950 (Watt)
    UPS Architectureline-interactive
    Number of phases input1 (230V)
    No. of batteries4
    Voltage230 (Volt)
    Battery capacity7 (Ah)
    Hold-up time (maks)3 (millisecond)
    Backup time (100% load)3 (Minute)
    Charging time7 (Hour)
    Chassis typeRack
    Filters / protectionOverload
    Filters / protectionSurge
    Filters / protectionCircuit
    Input power portsIEC-C20
    Output power ports6 x IEC-C13
    I/O connectors1 x USB (Type B)
    I/O connectors2 x RJ-45 LAN
    ColorBlack
    Dimensions
    • Wysokość: 132 (3U) mm
    • Szerokość: 483 (19) mm
    • Głębokość: 400 mm
    Weight31 (kilogram)
    Other features
    • Zastosowanie: Małe biuro i dom, Serwerownia
    • Temperatury pracy [°C]: 0 ÷ +40
    • Chłodzenie: Naturalne
    • Znamionowe napięcie wejściowe (wartość skuteczna) [V]:     ~ 230
    • Zakres napięcia wejściowego (wartości skuteczne) [V] i tolerancja [%]:     ~ 160 ÷ 264 (145 ÷ 280) 2
    • Częstotliwość znamionowa napięcia wejściowego [Hz]: 50
    • Zakres częstotliwości wejściowej [Hz] i tolerancja [Hz]: 45 ÷ 55 1
    • Progi przełączania: sieć UPS [V]: ~ 160 ÷ 264 (145 ÷ 280) 2 %
    • Znamionowe napięcie wyjściowe (wartość skuteczna) [V]:     ~ 230
    • Zakres napięcia wyjściowego (wartości skuteczne) [V] i tolerancja [%] - praca sieciowa : ~ 184 ÷ 264 (167 ÷ 280) 2
    • Zakres napięcia wyjściowego (wartości skuteczne) [V] i tolerancja [%] - praca rezerwowa : ~ 230 5
    • Kształt napięcia wyjściowego (przy pracy rezerwowej / sieciowej): Sinusoidalny / Tak jak na wejściu
    • Częstotliwość znamionowa napięcia wyjściowego [Hz]: 50
    • Zakres częstotliwości (tolerancja) - praca sieciowa [Hz]: Synchronicznie z siecią
    • Zakres częstotliwości (tolerancja) - praca rezerwowa [Hz]: 50 1
    • Filtracja napięcia wyjściowego : LC, filtr przeciwzakłóceniowy RFI/EMI, tłumik warystorowy
    • Progi przełączania: UPS sieć [V]: ~ 165 / 259 (150 / 275) 2 %
    • Czas przełączenia na pracę rezerwową [ms]: < 3
    • Czas powrotu na pracę sieciową [ms]: 0
    • Akumulatory wewnętrzne: 12 V / 7 Ah VRLA
    • Czas podtrzymania z baterii wewnętrznych (100 % / 80 % / 50 % Pmax) [min]: 3 / 4 / 8
    • Napięcie nominalne obwodu DC [V]: 48
    • Maksymalny czas ładowania baterii wewnętrznych UPS - po 80 % wyładowaniu baterii [h]: 7
    • Pozycja transportu: pozioma
    • Maksymalna długość przewodów wyjściowych [m]: < 10
    • Sygnalizacja: Akustyczno optyczna; diodowa
    • Filtr teleinformatyczny (linii danych) - RJ45: LAN 1 Gbit/s
    • Oprogramowanie monitorująco-zarządzające: PowerSoft Professional
    • Zimny start: tak
    Width500
    Height210
    Depth530
    Weight33000
    Description

    Generacja zasilaczy serii SINLINE USB HID umożliwia pełną ochronę zasilania zaawansowanych serwerów jedno i wieloprocesorowych, komputerów PC, terminali komputerowych oraz małych i średnich sieci.

    Cechy charakterystyczne:

    • Układ automatycznej regulacji napięcia sieciowego AVR (podwyższający) - umożliwia dostosowanie nieprawidłowego napięcia wejściowego do poziomu akceptowalnego przez odbiorniki bez użycia akumulatorów.
    • System Clear Digital Sinus (CDS) - umożliwia generację na wyjściu zasilacza UPS napięcia o czystym, sinusoidalnym kształcie przy pracy bateryjnej.
    • System Cool Battery Charging (CBC) - szybki i sprawny układ ładowania, który powoduje skrócenie czasu ładowania oraz wydłużenie okresu eksploatacji akumulatora zasilacza awaryjnego.
    • Zabezpieczenia przeciążeniowe, przeciwzwarciowe, przeciwprzepięciowe, przed nieprawidłowym podłączeniem.
    • Filtr sieci LAN (1 Gbit/s) umożliwia zabezpieczenie karty sieciowej przed skutkami oddziaływania przepięć.
    • Interfejs komunikacyjny USB HID zgodny z HID Power Devices możliwość współpracy UPS-a z innymi urządzeniami bez konieczności instalowania oprogramowania (zasilacz widoczny w systemie jako bateria).
    • Zimny start - możliwość uruchomienia urządzenia bez podłączenia do  sieci zasilającej
    • Sygnalizacja akustyczno-optyczna

    Rozszerzone progi przełączania (możliwe do ustawienia za pomocą oprogramowania PowerSoft) o następujących wartościach:

    • Sieć - ups: ~145V - ~280V +/- 2%
    • Ups - sieć: ~150V - ~275V +/- 2%
    • PowerSoft Professional bezpłatne oprogramowanie monitorująco - zarządzające pracą zasilaczy
    • Zaawansowana konfiguracja zdarzeń - możliwość tworzenia reguł uwarunkowanych od trybów pracy zasilacza, komunikatów oraz alarmów.
    • Opóźnienie przed ponownym załączeniem wyjścia zasilacza (wykorzystywane z opcją ponownego załączenia komputerów w systemach BIOS)