    Zasilacz awaryjny UPS NETLINE RT 3000 T/NETLRT-003K00/00


    €1027,76 ar pvn

    Artikuls: ST08506365
    Preces kods: T/NETLRT-003K00/00
    Ražotāja mājaslapa
    Garantija: 12 mēneši
    *
    Noliktava Piegāde Daudzums Cena
    PL
    LT

    Specifikācija
    Tips Line Interactive
    Ligzda (USB)
    Ligzda (IEC320)
    Ligzda (RS232)
    Ligzda (RJ-45)
    Nominālais efekts (VA) 3000
    Apparent power3000 VA
    Active power2700 (Watt)
    UPS Architectureline-interactive
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    No. of batteries6
    Voltage12 (Volt)
    Battery capacity9 (Ah)
    Hold-up time (maks)6 (millisecond)
    Backup time (100% load)4 (Minute)
    Charging time7 (Hour)
    Chassis typeTower
    Chassis typeRack
    Filters / protectionOverload
    Filters / protectionSurge
    Filters / protectionCircuit
    Special functions
    • Sygnalizacja akustyczno-optyczna
    • Wyświetlacz LCD
    Software

    WinPower

    Input power portsIEC-C20
    Output power ports1 x IEC-C19
    Output power ports8 x IEC-C13
    I/O connectors1 x EPO
    I/O connectors1 x RS-232 (COM)
    I/O connectors2 x RJ-45 LAN
    I/O connectors1 x USB (Type B)
    Environment requirements

    Temperatury pracy [°C]: 0 ÷ +40

    ColorBlack
    Dimensions

    86 (2U) x 438 x 608 mm

    Weight31 (kilogram)
    DesignationCE+WEEE
    Width600
    Height260
    Depth800
    Weight34500
    Description

    Zasilacz awaryjny UPS NETLINE RT 3000 T/NETLRT-003K00/00

    Zasilacze z serii NETLINE RT, są urządzeniami klasy LINE-INTERACTIVE (VI), przeznaczonymi do współpracy z urządzeniami zasilanymi z jednofazowej sieci energetycznej ~230 V. UPS-y stworzone zostały z myślą o zabezpieczeniu zasilania małej i średniej infrastruktury IT tj. serwerów, małych sieci komputerowych i stacji roboczych oraz innych urządzeń elektrycznych i elektronicznych. Dzięki uniwersalnemu rozwiązaniu obudowy (Rack / Tower) w prosty i szybki sposób możliwa jest zmiana sposobu instalacji urządzenia jako zasilacz wolnostojący lub element zabudowy szafy teleinformatycznej 19. Dodatkowo możliwość podpięcia do 10 modułów umożliwia uzyskanie bardzo długiego czasu podtrzymania.

    CECHY CHARAKTERYSTYCZNE:

    • Obudowa Rack / Tower dzięki uniwersalnemu rozwiązaniu obudowy w prosty i szybki sposób możliwa jest zmiana sposobu instalacji urządzenia (zmiana trybu Rack / Tower wyświetlacza LCD realizowana bez użycia narzędzi).
    • Interfejs komunikacyjny HID USB możliwość współpracy UPS-a z innymi urządzeniami bez konieczności instalowania oprogramowania
    • Możliwość zarządzania gniazdami wyjściowymi (2 sekcje) pozwala na odpowiednie dostosowanie działania urządzenia dla bardziej wymagających odbiorników.
    • Funkcja Start-on-battery umożliwia uruchomienie UPS nawet wówczas, gdy zasilanie z sieci nie jest dostępne (tzw. Zimny start).
    • Predykcja czasu podtrzymania określenie czasu autonomii UPS w czasie rzeczywistym.
    • Funkcja zdalnego awaryjnego wyłączania zasilania EPO (Emergency Power Off), umożliwiająca przerwanie dostarczania energii do urządzeń odbiorczych z wyjścia zasilacza w ekstremalnych sytuacjach, jak np. pożar.
    • System regulacji wartości napięcia sieciowego AVR (podwyższający i obniżający) umożliwia dostosowanie nieprawidłowego napięcia wejściowego do poziomu akceptowalnego przez odbiorniki (bez użycia akumulatorów).
    • Skalowalność (przedłużenie) czasu pracy autonomicznej dzięki możliwości podłączenia do zasilacza UPS maksymalnie 10 sztuk modułów bateryjnych.
    • Filtr  sieci  LAN  (10/100  Base-T)    umożliwia  zabezpieczenie  karty  sieciowej przed skutkami oddziaływania przepięć.
    • Możliwość wymiany baterii przez użytkownika.
    • Szerokie okno (zakres) napięcia wejściowego.
    • Komunikacja stanowa umożliwia sprawdzenie trybu pracy zasilacza oraz niskiego poziomu akumulatorów np. w systemach automatyki.

    KOMUNIKACJA

    • Interfejs komunikacyjny RS232 i USB HID.
    • Opcjonalna Sieciowa Karta Zarządzająca SNMP/HTTP i Karta Styków Bezpotencjałowych.

    Specifikācija
    Tips Line Interactive
    Ligzda (USB)
    Ligzda (IEC320)
    Ligzda (RS232)
    Ligzda (RJ-45)
    Nominālais efekts (VA) 3000
    Apparent power3000 VA
    Active power2700 (Watt)
    UPS Architectureline-interactive
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    No. of batteries6
    Voltage12 (Volt)
    Battery capacity9 (Ah)
    Hold-up time (maks)6 (millisecond)
    Backup time (100% load)4 (Minute)
    Charging time7 (Hour)
    Chassis typeTower
    Chassis typeRack
    Filters / protectionOverload
    Filters / protectionSurge
    Filters / protectionCircuit
    Special functions
    • Sygnalizacja akustyczno-optyczna
    • Wyświetlacz LCD
    Software

    WinPower

    Input power portsIEC-C20
    Output power ports1 x IEC-C19
    Output power ports8 x IEC-C13
    I/O connectors1 x EPO
    I/O connectors1 x RS-232 (COM)
    I/O connectors2 x RJ-45 LAN
    I/O connectors1 x USB (Type B)
    Environment requirements

    Temperatury pracy [°C]: 0 ÷ +40

    ColorBlack
    Dimensions

    86 (2U) x 438 x 608 mm

    Weight31 (kilogram)
    DesignationCE+WEEE
    Width600
    Height260
    Depth800
    Weight34500
    Description

    Zasilacz awaryjny UPS NETLINE RT 3000 T/NETLRT-003K00/00

    Zasilacze z serii NETLINE RT, są urządzeniami klasy LINE-INTERACTIVE (VI), przeznaczonymi do współpracy z urządzeniami zasilanymi z jednofazowej sieci energetycznej ~230 V. UPS-y stworzone zostały z myślą o zabezpieczeniu zasilania małej i średniej infrastruktury IT tj. serwerów, małych sieci komputerowych i stacji roboczych oraz innych urządzeń elektrycznych i elektronicznych. Dzięki uniwersalnemu rozwiązaniu obudowy (Rack / Tower) w prosty i szybki sposób możliwa jest zmiana sposobu instalacji urządzenia jako zasilacz wolnostojący lub element zabudowy szafy teleinformatycznej 19. Dodatkowo możliwość podpięcia do 10 modułów umożliwia uzyskanie bardzo długiego czasu podtrzymania.

    CECHY CHARAKTERYSTYCZNE:

    • Obudowa Rack / Tower dzięki uniwersalnemu rozwiązaniu obudowy w prosty i szybki sposób możliwa jest zmiana sposobu instalacji urządzenia (zmiana trybu Rack / Tower wyświetlacza LCD realizowana bez użycia narzędzi).
    • Interfejs komunikacyjny HID USB możliwość współpracy UPS-a z innymi urządzeniami bez konieczności instalowania oprogramowania
    • Możliwość zarządzania gniazdami wyjściowymi (2 sekcje) pozwala na odpowiednie dostosowanie działania urządzenia dla bardziej wymagających odbiorników.
    • Funkcja Start-on-battery umożliwia uruchomienie UPS nawet wówczas, gdy zasilanie z sieci nie jest dostępne (tzw. Zimny start).
    • Predykcja czasu podtrzymania określenie czasu autonomii UPS w czasie rzeczywistym.
    • Funkcja zdalnego awaryjnego wyłączania zasilania EPO (Emergency Power Off), umożliwiająca przerwanie dostarczania energii do urządzeń odbiorczych z wyjścia zasilacza w ekstremalnych sytuacjach, jak np. pożar.
    • System regulacji wartości napięcia sieciowego AVR (podwyższający i obniżający) umożliwia dostosowanie nieprawidłowego napięcia wejściowego do poziomu akceptowalnego przez odbiorniki (bez użycia akumulatorów).
    • Skalowalność (przedłużenie) czasu pracy autonomicznej dzięki możliwości podłączenia do zasilacza UPS maksymalnie 10 sztuk modułów bateryjnych.
    • Filtr  sieci  LAN  (10/100  Base-T)    umożliwia  zabezpieczenie  karty  sieciowej przed skutkami oddziaływania przepięć.
    • Możliwość wymiany baterii przez użytkownika.
    • Szerokie okno (zakres) napięcia wejściowego.
    • Komunikacja stanowa umożliwia sprawdzenie trybu pracy zasilacza oraz niskiego poziomu akumulatorów np. w systemach automatyki.

    KOMUNIKACJA

    • Interfejs komunikacyjny RS232 i USB HID.
    • Opcjonalna Sieciowa Karta Zarządzająca SNMP/HTTP i Karta Styków Bezpotencjałowych.