Close
(0) priekšmeti
You have no items in your shopping cart.
Visas kategorijas
    Filters
    Valoda
    Meklēt
    Ražotājs: CYBERPOWER

    Zasilacz awaryjny UPS OL6KERTHD 6000W/6000VA ON-LINE LCD


    €3624,92 ar pvn

    Artikuls: ST06727591
    Preces kods: OL6KERTHD
    Ražotāja mājaslapa
    Garantija: 24 mēneši
    *
    Noliktava Piegāde Daudzums Cena
    PL
    PL

    Specifikācija
    Tips Online
    Ligzda (USB)
    Tips Double Conversion Online
    Ligzda (RS232)
    Ligzda (RJ-45)
    Izejas jauda 6000
    Nominālais efekts (VA) 6000
    Ligzda (IEC320)
    Apparent power6 kVA
    Active power6000 (Watt)
    UPS Architectureon-line double conversion
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    Transfer time (max)0 (millisecond)
    Charging time4 (Hour)
    Chassis typeRack
    Chassis typeTower
    Filters / protectionSuppression
    Filters / protectionOverload
    Filters / protectionSurge
    Software

    PowerPanel Business

    Input power portsInput terminal
    Output power ports4 x IEC-C13
    Output power ports2 x IEC-C19
    Output power portsOutput terminals
    I/O connectors1 x EPO
    I/O connectors1 x USB (Type B)
    I/O connectors1 x RS-232 (COM)
    Environment requirements
    • Temperatura robocza: 32 ~ 104 (°F)
    • Temperatura robocza: 0 ~ 40 (°C)
    • Względna wilgotność robocza (bez kondensacji): 0 ~ 90 ( % )
    • Wysokość robocza: 0-10 000 stóp (0-3000 metrów) (stopy/metry)
    • Temperatura przechowywania: 23 ~ 113 (°F)
    • Temperatura przechowywania: -5 ~ 45 (°C)
    • Względna wilgotność przechowywania (bez kondensacji): 0 ~ 95 (%)
    • Wysokość przechowywania (stopy/metry): 0-14700 stóp (0-4500 metrów)
    • Rozproszenie ciepła online: 1613 (BTU/hr)
    • Wentylatory o zmiennej prędkości: 20 automatycznych kroków
    • Słyszalny hałas od 1M z powierzchni urządzenia: 43~66 dBA (0~100 % load)
    Accessories included
    • OL6KERTHD UPS
    • Szyny rack
    • Uchwyty rack
    • Pokrywa złącza terminalowego
    • Zestaw śrub
    • Przewód USB
    • Przewód Serial
    • Instrukcja obsługi
    ColorBlack
    Dimensions

    433 x 86,5 x 720 mm

    Weight42 (kilogram)
    Width620
    Height210
    Depth1100
    Weight30000
    Description

    Zasilacz awaryjny UPS OL6KERTHD 6000W/6000VA ON-LINE LCD

    CyberPower OL6KERTHD gwarantuje ochronę zasilania dla sprzętu IT, serwerów, stacji roboczych, NAS / urządzeń pamięci masowej, urządzeń telekomunikacyjnych, urządzeń sieciowych, systemów bezpieczeństwa / awaryjnych oraz systemów nadzoru. UPS wykorzystuje topologię podwójnej konwersji, aby zapewnić wysoką jakość mocy wyjściowej w kompaktowej konstrukcji. Zasilacz UPS jest kompatybilny z generatorem oraz wyposażony jest w akumulatory wymienialne podczas pracy bez konieczności przerywania zasilania. Posiada dodatkowy tryb ECO w celu oszczędzania energii i obniżenia kosztów energii.

    UPS może stosować rozszerzone moduły akumulatorowe (EBM) w celu przedłużenia czasu pracy i stosuje opatentowaną technologię zarządzania akumulatorami, aby zrównoważyć napięcie ciągu akumulatorów w celu uzyskania optymalnej ich żywotności. Model ten posiada kolorowy panel LCD z możliwością odchylania, który pozwala użytkownikom na błyskawiczne monitorowanie kluczowych informacji o zasilaniu oraz baterii. Oprogramowanie PowerPanel Power Management pozwala użytkownikowi na monitorowanie i zdalne zarządzanie UPS w czasie rzeczywistym.

    • Topologia UPS (podwójnej konwersji) online
    • Konstrukcja o wysokiej gęstości
    • Wysoki współczynnik mocy wyjściowej
    • Odchylany panel LCD
    • Ochrona przed zakłóceniami i przepięciami
    • Kompatybilność z generatorem
    • Baterie wymienialne w trakcie pracy (Hot-swap)
    • Inteligentne zarządzanie baterią (SBM)
    • Możliwość zdalnego zarządzania SNMP/HTTP
    • Tryb ECO
    • Kolorowy panel LCD
    • Technologia szybkiego ładowania
    • Automatycznie obracany wyświetlacz LCD
    • Kluczowe/niekluczowe obciążenia
    • Technologia zarządzania baterią
    • Rozszerzony moduł akumulatorowy (EBM)
    • Port wyłącznika awaryjnego (EPO)
    • Oprogramowanie do zarządzania PowerPanel
    Apparent power6 kVA
    Active power6000 (Watt)
    UPS Architectureon-line double conversion
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    No. of batteries12
    Voltage144 (Volt)
    Transfer time (max)0 (millisecond)
    Backup time (100% load)2.4 (Minute)
    Charging time4 (Hour)
    Chassis typeRack
    Filters / protectionOverload
    Filters / protectionSurge
    Special functions
    • Topologia UPS (podwójnej konwersji) online
    • Konstrukcja o wysokiej gęstości
    • Wysoki współczynnik mocy wyjściowej
    • Odchylany panel LCD
    • Ochrona przed zakłóceniami i przepięciami
    • Kompatybilność z generatorem
    • Baterie wymienialne w trakcie pracy (Hot-swap)
    • Inteligentne zarządzanie baterią (SBM)
    • Możliwość zdalnego zarządzania SNMP/HTTP
    • Tryb ECO
    • Kolorowy panel LCD
    • Technologia szybkiego ładowania
    • Automatycznie obracany wyświetlacz LCD
    • Kluczowe/niekluczowe obciążenia
    • Technologia zarządzania baterią
    • Rozszerzony moduł akumulatorowy (EBM)
    • Port wyłącznika awaryjnego (EPO)
    • Oprogramowanie do zarządzania PowerPanel
    Input power portsInput terminal
    Output power ports4 x IEC-C13
    Output power ports2 x IEC-C19
    I/O connectors1 x USB (Type B)
    I/O connectors1 x RS-232 (COM)
    I/O connectors2 x RJ-45 LAN
    Environment requirements
    • Temperatura robocza 0 - 40°C
    • Względna wilgotność robocza (bez kondensacji) 0 - 90%
    • Wysokość robocza 0-3000 metrów
    • Temperatura przechowywania -5 - 45°C
    • Względna wilgotność przechowywania (bez kondensacji) 0 - 95%
    • Wysokość przechowywania 0-4 500 metrów
    ColorBlack
    Dimensions

    433 x 86.5 x 720 mm

    Weight42 (kilogram)
    Width1095
    Height205
    Depth600
    Weight42000
    Description

    CyberPower OL6KERTHD gwarantuje ochronę zasilania dla sprzętu IT, serwerów, stacji roboczych, NAS / urządzeń pamięci masowej, urządzeń telekomunikacyjnych, urządzeń sieciowych, systemów bezpieczeństwa / awaryjnych oraz systemów nadzoru. UPS wykorzystuje topologię podwójnej konwersji, aby zapewnić wysoką jakość mocy wyjściowej w kompaktowej konstrukcji. Zasilacz UPS jest kompatybilny z generatorem oraz wyposażony jest w akumulatory wymienialne podczas pracy bez konieczności przerywania zasilania. Posiada dodatkowy tryb ECO w celu oszczędzania energii i obniżenia kosztów energii.

    UPS może stosować rozszerzone moduły akumulatorowe (EBM) w celu przedłużenia czasu pracy i stosuje opatentowaną technologię zarządzania akumulatorami, aby zrównoważyć napięcie ciągu akumulatorów w celu uzyskania optymalnej ich żywotności. Model ten posiada kolorowy panel LCD z możliwością odchylania, który pozwala użytkownikom na błyskawiczne monitorowanie kluczowych informacji o zasilaniu oraz baterii. Oprogramowanie PowerPanel Power Management pozwala użytkownikowi na monitorowanie i zdalne zarządzanie UPS w czasie rzeczywistym.


    Specifikācija
    Tips Online
    Ligzda (USB)
    Tips Double Conversion Online
    Ligzda (RS232)
    Ligzda (RJ-45)
    Izejas jauda 6000
    Nominālais efekts (VA) 6000
    Ligzda (IEC320)
    Apparent power6 kVA
    Active power6000 (Watt)
    UPS Architectureon-line double conversion
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    Transfer time (max)0 (millisecond)
    Charging time4 (Hour)
    Chassis typeRack
    Chassis typeTower
    Filters / protectionSuppression
    Filters / protectionOverload
    Filters / protectionSurge
    Software

    PowerPanel Business

    Input power portsInput terminal
    Output power ports4 x IEC-C13
    Output power ports2 x IEC-C19
    Output power portsOutput terminals
    I/O connectors1 x EPO
    I/O connectors1 x USB (Type B)
    I/O connectors1 x RS-232 (COM)
    Environment requirements
    • Temperatura robocza: 32 ~ 104 (°F)
    • Temperatura robocza: 0 ~ 40 (°C)
    • Względna wilgotność robocza (bez kondensacji): 0 ~ 90 ( % )
    • Wysokość robocza: 0-10 000 stóp (0-3000 metrów) (stopy/metry)
    • Temperatura przechowywania: 23 ~ 113 (°F)
    • Temperatura przechowywania: -5 ~ 45 (°C)
    • Względna wilgotność przechowywania (bez kondensacji): 0 ~ 95 (%)
    • Wysokość przechowywania (stopy/metry): 0-14700 stóp (0-4500 metrów)
    • Rozproszenie ciepła online: 1613 (BTU/hr)
    • Wentylatory o zmiennej prędkości: 20 automatycznych kroków
    • Słyszalny hałas od 1M z powierzchni urządzenia: 43~66 dBA (0~100 % load)
    Accessories included
    • OL6KERTHD UPS
    • Szyny rack
    • Uchwyty rack
    • Pokrywa złącza terminalowego
    • Zestaw śrub
    • Przewód USB
    • Przewód Serial
    • Instrukcja obsługi
    ColorBlack
    Dimensions

    433 x 86,5 x 720 mm

    Weight42 (kilogram)
    Width620
    Height210
    Depth1100
    Weight30000
    Description

    Zasilacz awaryjny UPS OL6KERTHD 6000W/6000VA ON-LINE LCD

    CyberPower OL6KERTHD gwarantuje ochronę zasilania dla sprzętu IT, serwerów, stacji roboczych, NAS / urządzeń pamięci masowej, urządzeń telekomunikacyjnych, urządzeń sieciowych, systemów bezpieczeństwa / awaryjnych oraz systemów nadzoru. UPS wykorzystuje topologię podwójnej konwersji, aby zapewnić wysoką jakość mocy wyjściowej w kompaktowej konstrukcji. Zasilacz UPS jest kompatybilny z generatorem oraz wyposażony jest w akumulatory wymienialne podczas pracy bez konieczności przerywania zasilania. Posiada dodatkowy tryb ECO w celu oszczędzania energii i obniżenia kosztów energii.

    UPS może stosować rozszerzone moduły akumulatorowe (EBM) w celu przedłużenia czasu pracy i stosuje opatentowaną technologię zarządzania akumulatorami, aby zrównoważyć napięcie ciągu akumulatorów w celu uzyskania optymalnej ich żywotności. Model ten posiada kolorowy panel LCD z możliwością odchylania, który pozwala użytkownikom na błyskawiczne monitorowanie kluczowych informacji o zasilaniu oraz baterii. Oprogramowanie PowerPanel Power Management pozwala użytkownikowi na monitorowanie i zdalne zarządzanie UPS w czasie rzeczywistym.

    • Topologia UPS (podwójnej konwersji) online
    • Konstrukcja o wysokiej gęstości
    • Wysoki współczynnik mocy wyjściowej
    • Odchylany panel LCD
    • Ochrona przed zakłóceniami i przepięciami
    • Kompatybilność z generatorem
    • Baterie wymienialne w trakcie pracy (Hot-swap)
    • Inteligentne zarządzanie baterią (SBM)
    • Możliwość zdalnego zarządzania SNMP/HTTP
    • Tryb ECO
    • Kolorowy panel LCD
    • Technologia szybkiego ładowania
    • Automatycznie obracany wyświetlacz LCD
    • Kluczowe/niekluczowe obciążenia
    • Technologia zarządzania baterią
    • Rozszerzony moduł akumulatorowy (EBM)
    • Port wyłącznika awaryjnego (EPO)
    • Oprogramowanie do zarządzania PowerPanel
    Apparent power6 kVA
    Active power6000 (Watt)
    UPS Architectureon-line double conversion
    The shape of the output voltageFull sine wave
    Number of phases input1 (230V)
    No. of batteries12
    Voltage144 (Volt)
    Transfer time (max)0 (millisecond)
    Backup time (100% load)2.4 (Minute)
    Charging time4 (Hour)
    Chassis typeRack
    Filters / protectionOverload
    Filters / protectionSurge
    Special functions
    • Topologia UPS (podwójnej konwersji) online
    • Konstrukcja o wysokiej gęstości
    • Wysoki współczynnik mocy wyjściowej
    • Odchylany panel LCD
    • Ochrona przed zakłóceniami i przepięciami
    • Kompatybilność z generatorem
    • Baterie wymienialne w trakcie pracy (Hot-swap)
    • Inteligentne zarządzanie baterią (SBM)
    • Możliwość zdalnego zarządzania SNMP/HTTP
    • Tryb ECO
    • Kolorowy panel LCD
    • Technologia szybkiego ładowania
    • Automatycznie obracany wyświetlacz LCD
    • Kluczowe/niekluczowe obciążenia
    • Technologia zarządzania baterią
    • Rozszerzony moduł akumulatorowy (EBM)
    • Port wyłącznika awaryjnego (EPO)
    • Oprogramowanie do zarządzania PowerPanel
    Input power portsInput terminal
    Output power ports4 x IEC-C13
    Output power ports2 x IEC-C19
    I/O connectors1 x USB (Type B)
    I/O connectors1 x RS-232 (COM)
    I/O connectors2 x RJ-45 LAN
    Environment requirements
    • Temperatura robocza 0 - 40°C
    • Względna wilgotność robocza (bez kondensacji) 0 - 90%
    • Wysokość robocza 0-3000 metrów
    • Temperatura przechowywania -5 - 45°C
    • Względna wilgotność przechowywania (bez kondensacji) 0 - 95%
    • Wysokość przechowywania 0-4 500 metrów
    ColorBlack
    Dimensions

    433 x 86.5 x 720 mm

    Weight42 (kilogram)
    Width1095
    Height205
    Depth600
    Weight42000
    Description

    CyberPower OL6KERTHD gwarantuje ochronę zasilania dla sprzętu IT, serwerów, stacji roboczych, NAS / urządzeń pamięci masowej, urządzeń telekomunikacyjnych, urządzeń sieciowych, systemów bezpieczeństwa / awaryjnych oraz systemów nadzoru. UPS wykorzystuje topologię podwójnej konwersji, aby zapewnić wysoką jakość mocy wyjściowej w kompaktowej konstrukcji. Zasilacz UPS jest kompatybilny z generatorem oraz wyposażony jest w akumulatory wymienialne podczas pracy bez konieczności przerywania zasilania. Posiada dodatkowy tryb ECO w celu oszczędzania energii i obniżenia kosztów energii.

    UPS może stosować rozszerzone moduły akumulatorowe (EBM) w celu przedłużenia czasu pracy i stosuje opatentowaną technologię zarządzania akumulatorami, aby zrównoważyć napięcie ciągu akumulatorów w celu uzyskania optymalnej ich żywotności. Model ten posiada kolorowy panel LCD z możliwością odchylania, który pozwala użytkownikom na błyskawiczne monitorowanie kluczowych informacji o zasilaniu oraz baterii. Oprogramowanie PowerPanel Power Management pozwala użytkownikowi na monitorowanie i zdalne zarządzanie UPS w czasie rzeczywistym.